Home / Guides / Loft and pipe insulation you can do yourself

Loft and pipe insulation you can do yourself

Energy Saving Trust’s depth is at least 270 mm. The first layer goes between the joists, the second across them. Do not cover vents, do not bury cables, and do not start if the loft is damp.

By Guy Bridges, a UK engineer. Published 24 November 2026. Checked 24 November 2026.

An uninsulated roof is a large hole in the heating bill. Energy Saving Trust says an uninsulated home loses around 25% of its heat through the roof, and that loft insulation fitted properly can last around 40 years. The DIY version is mineral wool at ceiling level, and only in a loft that is dry, easy to get into, and not a room.

When not to start

Do not add insulation over a damp loft, a leaking roof, or a flat roof. EST says to fix the cause of the damp first, and to get advice before insulating if you are unsure. They also say they do not recommend spraying foam onto the underside of a damaged roof as a way of avoiding the repair. A loft you live in, a room-in-the-roof, or insulation between the rafters is a different job, for an installer, because the ventilation path and the cold surfaces move.

If you are in Northern Ireland, EST notes that building regulations there require adequate ventilation when loft insulation goes in, which often means adding vents. Check with building control.

Grants sometimes pay for this. The grants note says which schemes were open on 24 November 2026, including the ones that have closed. Do not assume a free loft is still on offer because a leaflet from 2024 said so.

The depth, and the two directions

EST says current building regulations recommend a minimum of 270 mm of mineral wool. Measure what you already have. If it is dry, even and not compressed, keep it and add to it. If it is sodden, matted or chewed, take that part up and start again.

Their savings for a typical three-bedroom semi-detached house:

Job Great Britain, per year Northern Ireland, per year
0 mm to 270 mm about £190 about £240
120 mm to 270 mm about £17 about £20

The same page puts professional installation around £750 in Great Britain for a bare loft brought up to 270 mm, and around £600 to top up from 120 mm. Northern Ireland installation figures on that page are higher. Prices and savings move with the market they modelled. Read the page.

Joist spacing is commonly 400 mm or 600 mm. Rolls are often perforated so you can split them to width. The first layer goes between the joists, up to the top of the timber. The second layer goes across the joists, at right angles, until the total depth is at least 270 mm. The cross layer is what stops the joists themselves acting as a row of cold bridges.

The things people cover by mistake

Vents at the eaves are the air path that keeps the cold side of the roof dry. EST is blunt: do not cover vents, grilles or airbricks. If you are not sure the loft will still be ventilated, stop and ask before you fill the edges. Blocked eaves are how a warmer ceiling becomes a wet roof.

Cables are a fire risk if they are buried. Energy Saving Trust says so directly, and says to talk to a qualified electrician if you are in doubt. Recessed lights need covers that are meant for insulation, or the lamps need to be ones you are allowed to cover. The LED note is the companion to that. Do not decide it is fine because the wool is soft.

Walk on the joists, or on a board you have put down as a temporary path. A foot through the ceiling is the usual DIY injury, and it is a long way down.

Storage, tanks and pipes

If you need to store boxes, raise the boards on loft legs or battens so the wool can stay at full thickness underneath, and leave a gap so the air can move. Squashing 270 mm down to the height of a joist throws away the cross layer you just bought.

Insulating at ceiling level makes the loft colder. That is the point: the heat stays downstairs. Pipes and cold-water tanks in that colder loft are more likely to freeze. EST says the tank should be lagged around the sides and over the top, with no insulation underneath it, so a little heat from below can still reach the base. Pipes get foam tube, the thickest that will fit, closed at the ends and around bends, including pipes in a garage or a void. Their pipe-insulation saving is small and dated: around £6 a year, based on fuel prices as of January 2024, for a typical gas-heated three-bedroom semi in Great Britain. The freeze protection is the stronger reason.

Lag the loft hatch and draught-proof the frame. A cold loft will otherwise pour air through the landing ceiling. Strips are covered in the draught-proofing note.

Turn the heating and hot water off before you handle hot pipes.

Buying the materials, and hiring it out

A search finds rolls, foam tube and loft legs. Check the thickness and the width against the joists you measured. This is not a product pick.

If the hatch is tiny, the roof is flat, or you do not want to be up there, hire it. EST suggests TrustMark for installers, more than one quote, and a written scope that includes ventilation. Ask what they will do with cables and downlights. Take photographs before and after so you know the depth that went in.

Common questions

How deep should loft insulation be?

Energy Saving Trust says current building regulations recommend at least 270 mm of mineral wool. If you already have 120 mm in sound condition, you are topping up by at least 150 mm, laid across the joists. From nothing, you need the full 270 mm.

What does Energy Saving Trust say it saves?

For a typical three-bedroom semi-detached home, going from no insulation to 270 mm is about £190 a year in Great Britain and £240 in Northern Ireland. Topping up from 120 mm to 270 mm is about £17 a year in Great Britain and £20 in Northern Ireland. Professional installation is around £750 and £600 for those two jobs in Great Britain. An uninsulated home can lose around 25% of its heat through the roof. These are their figures, for that house type.

Can I board the loft for storage afterwards?

Only if the boards sit above the insulation on legs or battens, with a ventilation gap, and the wool is not squashed. Squashed mineral wool insulates less. Energy Saving Trust also says not to put insulation under a cold-water tank. The tank is lagged around the sides and over the top.

Sources